The SNMP HPE ProLiant System Health sensor monitors the system health of an HPE ProLiant server via the Simple Network Management Protocol (SNMP).
SNMP HPE ProLiant System Health Sensor
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
Sensor in Other Languages
Dutch: SNMP HPE ProLiant Systeemstatus
French: HPE ProLiant état du système (SNMP)
German: SNMP HPE ProLiant Systemzustand
Japanese: SNMP HPE ProLiant システム正常性
Portuguese: Funcionamento do sistema HPE ProLiant (SNMP)
Russian: Работоспособность системы HPE ProLiant по SNMP
Simplified Chinese: SNMP HPE ProLiant 系统运行状况
Spanish: Salud de sistema HPE ProLiant (SNMP)
Remarks
For Gen9 servers or earlier: This sensor requires HPE Insight Management Agents and HPE Insight Management WBEM Providers to be installed on the target device.
For Gen10 servers: Use the HPE Integrated Lights Out (iLO) interface as the parent device for this sensor.
This sensor has predefined limits for temperatures and broken frames. You can change these limits individually in the channel settings.
Redundant array of independent disks (RAID) controllers that have no hard disks assigned might cause the Downstatus. In this case, deactivate the respective controllers in the HPE ProLiant BIOS to avoid sensor errors.
This sensor supports monitoring iLO as of iLO version 3. We recommend that you use at least iLO 4.
This sensor supports the IPv6 protocol.
This sensor has a low performance impact.
This sensor uses lookups to determine the status values of one or more channels. This means that possible states are defined in a lookup file. You can change the behavior of a channel by editing the lookup file that the channel uses. For details, see section Define Lookups.
Detailed Requirements
Requirement
Description
HPE system management tools
For Gen9 servers or earlier, this sensor needs a specific HPE system management tool to be installed on the target device to report data via SNMP: HPE Insight Management Agents. To receive SNMP data from redundant array of independent disks (RAID) controllers, you additionally need HPE Insight Management Agents. For Gen10 servers, this sensor no longer requires HPE system management tools.
For Gen9 servers or earlier, some of the HPE object identifiers (OID) that this sensor uses are only accessible via the iLO interface. If this sensor throws an error that it cannot find "such device types", create a device that points to the address of the HPE iLO interface (if available) and add the sensor to this device. We recommend that you use the Agentless Management feature with configured SNMP. You can set this up in the iLO configuration interface under Administration | Management | SNMP Settings. For Gen10 servers, use the HPE iLO interface as parent device for this sensor.
Add Sensor
The Add Sensor dialog appears when you manually add a new sensor to a device. It only shows the settings that are required to create the sensor. You can change nearly all settings on the sensor's Settings tab after creation.
Basic Sensor Settings
Click the Settings tab of a sensor to change its settings.
If the name contains angle brackets (<>), PRTG replaces them with braces ({}) for security reasons. For more information, see the Knowledge Base: What security features does PRTG include?
This setting is for your information only. You cannot change it.
Tags
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
It is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).
For performance reasons, it can take some minutes until you can filter for new tags that you added.
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
snmphpesystemhealthsensor
systemhealth
snmphpe
hpe
Priority
Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority () to the highest priority ().
Usually, a sensor connects to the IP Address/DNS Name of the parent device. See the device settings for details. For some sensors, you can explicitly define the monitoring target in the sensor settings.
Sensor Display
Sensor Display
Setting
Description
Primary Channel
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab.
Graph Type
Define how different channels are shown for this sensor:
Show channels independently (default): Show a graph for each channel.
Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic. You cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).
Stack Unit
This setting is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.
Inherited Settings
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Root Group Settings, section Scanning Interval.
Schedules, Dependencies, and Maintenance Window
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.
Schedules, Dependencies, and Maintenance Window
For more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.
Access Rights
Access Rights
For more information, see section Root Group Settings, section Access Rights.
Channel Unit Configuration
Which channel units are available depends on the sensor type and the available parameters. If no configurable channels are available, this field shows No configurable channels.
Channel Unit Configuration
For more information, see section Root Group Settings, section Channel Unit Configuration.
Channel List
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel
Description
CPU Fan Status
The CPU fan status
Up status: OK
Warning status: Degraded
Down status: Failed
Unknown status: Other
Disk Controller Status
The disk controller status
Up status: OK
Warning status: Degraded
Down status: Failed
Unknown status: Other
Downtime
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status
Fans Broken
The number of broken fans
Fans Running
The number of running fans
Fault Tolerant Fans Broken
The number of fault-tolerant broken fans
Fault Tolerant Fans Running
The number of fault-tolerant running fans
Overall Status
The overall status
Up status: OK
Warning status: Degraded
Down status: Failed
Unknown status: Other
This channel is the primary channel by default.
Power Consumption [#]
The power consumption in watts (W)
Power Consumption [#] (%)
The power consumption in percent
Power Supply [#] Condition
The power supply condition
Up status: OK
Down status: Degraded, Failed
Unknown status: Other
Power Supply [#] Status
The power supply status
Up status: No Error
Down status: Bist Failure, Brownout, Calibration Table Invalid, Dac Failure, Eprom Failure, Fan Failure, General Failure, Give Up On Startup, Interlock Open, No Power Input, Nvram Invalid, Orring Diode Failed, Ram Test Failed, Temp Failure, Voltage Channel Failed, Vref Failure